[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_custom_heading text=”BIOGAS” font_container=”tag:h2|font_size:15|text_align:left|color:%233a3a3a|line_height:1″ google_fonts=”font_family:Noto%20Sans%3Aregular%2Citalic%2C700%2C700italic|font_style:400%20regular%3A400%3Anormal” link=”url:https%3A%2F%2Fwww.jacobi.net%2Fzh-hans%2Fbiogas%2F” el_class=”eg-spaced-title”][vc_separator color=”black”][ultimate_spacer height=”50″][vc_column_text el_class=”eg-custom-textBox”]
Hydrogen sulphide (H₂S) removal from Biogas
[/vc_column_text][ultimate_spacer height=”20″][vc_column_text el_class=”eg-custom-textBox”]Biogas is produced by the digestion of organic matter in landfills and anaerobic digesters. Hydrogen sulphide (H₂S) is formed during the anaerobic digestion of sulphur-containing molecules, such as sulphur-containing amino acids within proteins.
Hydrogen sulphide (H₂S) needs to be removed before the combustion engine, because there it is converted to SO₂/SO₃ and results in:
- Higher maintenance cost due to corrosion
- A negative effect on the engine oil, meaning it needs to be changed more frequently.
- A contribution to the SO₂/SO₃ emissions of the engine exhaust.
Hydrogen sulphide (H₂S) concentrations can also be too high for feeding to the supply grid. In general, a biomethane quality of >99% methane needs to be achieved to be able to feed to the grid. [/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_row_inner][vc_column_inner][ultimate_spacer height=”50″][vc_custom_heading text=”BIOGAS: MOBILE FILTER” font_container=”tag:h2|font_size:15|text_align:left|color:%233a3a3a|line_height:1″ google_fonts=”font_family:Noto%20Sans%3Aregular%2Citalic%2C700%2C700italic|font_style:400%20regular%3A400%3Anormal” el_class=”eg-spaced-title”][vc_separator color=”black”][ultimate_spacer height=”40″][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column width=”1/5″][vc_single_image image=”44894″ img_size=”200×200″ onclick=”custom_link” link=”https://services.jacobi.net/industrial-filter-solutions/ecoflow-mobile-filters/”][/vc_column][vc_column width=”4/5″][vc_column_text el_class=”eg-custom-textBox”]
EcoFlow™
Hydrogen sulphide (H₂S) removal filters from Jacobi’s EcoFlow™ mobile filter range are usually installed before the water condenser in the biogas purification process.
Jacobi has a full range of mobile filters for flow rates between 75 and 4,000 m³/h biogas per filter. Our wide range of rental EcoFlow™ filters are offered via local sales offices, avoiding international transport.[/vc_column_text][ultimate_spacer height=”20″][ult_buttons btn_title=”View Filter Range” btn_link=”url:https%3A%2F%2Fservices.jacobi.net%2Findustrial-filter-solutions%2Fecoflow-mobile-filters%2F|title:EcoFlow%E2%84%A2%20Mobile%20Filters” btn_size=”ubtn-small” btn_title_color=”#ffffff” btn_bg_color=”rgba(10,1,1,0.4)” icon_size=”32″ btn_icon_pos=”ubtn-sep-icon-at-left”][/vc_column][/vc_row][vc_row][vc_column][vc_row_inner][vc_column_inner][ultimate_spacer height=”50″][vc_custom_heading text=”BIOGAS: SOLUTIONS” font_container=”tag:h2|font_size:15|text_align:left|color:%233a3a3a|line_height:1″ google_fonts=”font_family:Noto%20Sans%3Aregular%2Citalic%2C700%2C700italic|font_style:400%20regular%3A400%3Anormal” el_class=”eg-spaced-title”][vc_separator color=”black”][ultimate_spacer height=”40″][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column width=”1/5″][vc_single_image image=”44876″ img_size=”200×200″][/vc_column][vc_column width=”4/5″][vc_column_text el_class=”eg-custom-textBox”]
Auxiliary equipment and additional services
In addition to mobile filters and different media, Jacobi Services also offers various items of auxiliary equipment and additional services for hydrogen sulphide (H₂S) removal from biogas, including:
- Selection of the type and number of EcoFlow™ filters. The selection depends on the flowrate and the estimated annual activated carbon consumption.
- A series of removable insulation jackets to prevent condensation of water and to keep the relative humidity within an acceptable range for EcoFlow™ mobile filters.
- The capabilities of the Jacobi France laboratory for externally accredited self-ignition testing of virgin or spent activated carbon.
[/vc_column_text][/vc_column][/vc_row][vc_row][vc_column][ultimate_spacer height=”20″][/vc_column][/vc_row][vc_row][vc_column width=”1/5″][vc_single_image image=”44885″ img_size=”200×200″][/vc_column][vc_column width=”4/5″][vc_column_text el_class=”eg-custom-textBox”]
Recycling and reactivation
Depending on the region and the composition of the spent carbon, different recycling or disposal routes are possible. Impregnated spent activated carbons are currently not recyclable. [/vc_column_text][ultimate_spacer height=”20″][ult_buttons btn_title=”Find Out More” btn_link=”url:https%3A%2F%2Fservices.jacobi.net%2Findustrial-filter-solutions%2Fspent-media-recycling-valorisation%2F|title:Reactivation” btn_size=”ubtn-small” btn_title_color=”#ffffff” btn_bg_color=”rgba(10,1,1,0.4)” icon_size=”32″ btn_icon_pos=”ubtn-sep-icon-at-left”][/vc_column][/vc_row][vc_row][vc_column][ultimate_spacer height=”20″][/vc_column][/vc_row][vc_row][vc_column width=”1/5″][vc_single_image image=”44867″ img_size=”200×200″][/vc_column][vc_column width=”4/5″][vc_column_text el_class=”eg-custom-textBox”]
Activated carbon
The AddSorb™ VA6 range of impregnated activated carbons are advised for hydrogen sulphide (H₂S) removal from biogas. It is not recommended to mix the product with a siloxane removal product because it is difficult or impossible to establish the volume ratios that are needed. [/vc_column_text][/vc_column][/vc_row][vc_row][vc_column][ultimate_spacer height=”40″][vc_separator][ultimate_spacer height=”40″][/vc_column][/vc_row][vc_row el_class=”eg-custom-formStyles”][vc_column][vc_column_text el_class=”eg-custom-formHeader”]